YOUR POSITIONㄩHOME-COMPANY INTRODUCTION
 
 
1 2 3 4 5 6
 
GLB-360TRD
- This instrument is portable multitester designated for measurement of weak current circuits.
- Panel face protection cover which serves also as a stand is employed.
- Our technology has made it possible to measure high resistance (up to maximum 200m次) with low voltage.
- Band meter of drop shock type with high sensitivity has beer employed.
- Overload protection circuit up to maximum 230V is provided.
- DCV=O.1m/O.25/2.5/IO/250v ㊣3%f.s. 1000㊣5%f.s.
- ACV=10/50/250v㊣4%f.s. 1000v㊣5%f.s.
- DCV=50米/2.5m/25m/0.25A㊣3%f.s.
- 次=2k/20k2M+3% of arc. 200M㊣5% of arc.
- C=10米F
- dB=-10dB-+62dB
- L1=1.5米/150米/15m/150mA
- hFE=0-1000
- Power source=R6(l.5V)X2
- Size=160-128X41mm
- Weight=320g
- Box:GTY:40PCS N.W.:14KGS G.W.:15KGS M:48*33*28cm
 
GLB-360TRNP
- Range DCV=0.1/0.5/2.5/10/50/250/1000V
- ACV=lO/50/250/1OOOV
- DCmA=0.05/2.5/25/250mA
- 次=X1/X10/X100/X1K/X10K(Mid scale 20)
- dB=-10-+22dB
- hFE=0-1000 (W/TR CONNCOTOR)
- Sensitivity=DC 20K次/V,AC9K次/V
- Accuracy=DCV,DCmA:㊣3% f.s. DCA,ACV,次:㊣5% f.s.
- Size=145X98X35mm
- Weigh=220g
- Continuity check with buzzer or LED indicator
- Box:GTY:40PCS N.W.:14KGS G.W.:15KGS M:44*33*28cm
 
GLB-960TR
- Excellent DC resolution factor of 2mV and expanded resistance measurement from 0.2次 to 20M次. .
- Series capacitor terminal(OUTPUT)blocks DC to enable measurement of only AC components.
- A large and bright meter with a scale length of 80mm and its sensitivity of 44米 A at full scale.
- Fuse and diode protection.
- Measures hFE of transistor directly.
- DCV=100m/500m/2.5/10/50/250/1000v(20k次/V)㊣3%f.s.25kV(with Hvprobe)
- ACV=10/50/250/1000v(9k次/V)㊣4%f.s.
- DCA=50米/2.Sm/25m/250mA㊣3%f.s.(2.5A,10A㊣5%f.s.)
- 次=2/20k/200k/2M/20m次 MAX㊣3% of arc.
- dB=-10-62dB
- Ll=150米/1.5m/15m/150mA
- hFE=0-1000(w/TR conncetor)
- Power source=R6(1.5V)X2,6F22(9V)X1
- Size.weight=150XI00X36mm.280g
 
GLB-960TRE
- Excellent DC resolution factor of 2mV and expanded resistance measurement from 0.2次 to 20M次.
- Series capacitor terminal(OUTPUT)blocks DC to enable measurement of only AC components.
- A large and bright meter with a scale length of 80mm and its sensitivity of 44米 A at full scale.
- Fuse and diode protection.
- Measures hFE of transistor directly.
- DCV=100m/500m/2.5/10/50/250/1000v(20k次/V)㊣3%f.s.25kV(with Hvprobe)
- ACV=10/50/250/1000v(9k次/V)㊣4%f.s.
- DCA=50米/2.5m/25m/250mA㊣3%f.s.(2.5A,10A㊣5%f.s.)
- 次=2k/20k/200k/2M/20m 次 MAX㊣3% of arc.
- dB=-10-62dB
- L1=150米/1.5m/15m/150mA
- hFE=0-1000(w/TR conncetor)
- Power source=R6(1.5V)X2,6F22(9V)X1
- Size.weight=150X100X36mm.280g
 
GLB-1109
- Range:DCV:0.1-0.5-2.5-10-50-250-1000V ACV:10-50-250-1000V
- DcmA:O.O5-2.5-25-250mA
- AcA:15A
- 次:X1,X10,X1K,X10K
- dB:-10-+22dB
- Sensitivity:DC 20K次/V,AC 9K次/V
- Accuracy:DC:㊣3% F,S AC 次:㊣5% F,S
- Size:160X98X45mm
- Weight:250g
 
1 2 3 4 5 6
 
Copyright:Wuxi GLOBE ELECTRONICS METER CO.,LTD.
Best with IE 5.0,800*600 Powered By www.wxall.com